B超室医院感染管理制度
第一篇:b超室医院感染管理制度b超室医院感染管理制度
一、保持诊室整齐,非诊疗用品不得存放入内。
二、空气消毒每日一次,每次1小时。如有传染病人(特别是呼吸道感染),及时进行消毒。
三、物体表面、地面每日清洁两次,湿式清扫,如遇污染时,及时消毒
四、b超探头用含有抗菌药物的偶合剂。
五、诊疗床单等每日更换,如遇感染病人时,一用一换(提倡使用一次性中单)。
六、所有医疗废弃物(手套、帽子、口罩、使用后的卫生纸)均存放入专用垃圾箱内,交专职人员收集,送焚烧,不得随地丢弃。
七、工作人员注意手卫生,配备洗手设施或速干手消毒剂,接触病人皮肤、粘膜后要及时洗手。
八、将医院感染有关资料存放入专用文件夹内。
第二篇:b超室、心电图室医院感染管理制度b超室、心电图室医院感染管理制度
1、工作人员着装整洁,检查病人前后均应洗手或手消毒。
2、检查室内防尘、通风、干燥。
3、保持诊疗床等物体表面清洁,定期更换床单、枕套等,如被污染应及时更换。
4、超声探头一人一用一清洁一消毒或灭菌;每班次检查结束后,对超声探头进行彻底清洁、消毒处理,干燥保存。
5、使用后的心电图电极头用75%酒精擦拭消毒;心电图机身及导联线保持清洁。
第三篇:b超室、心电图室医院感染管理制度b超室、心电图室医院感染管理制度
1、工作人员着装整洁,检查病人前后均应洗手或手消毒。
2、检查室内防尘、通风、干燥。空气消毒每日两次,并有记录。如有传染病人(特别是呼吸道感染)技术进行消毒。
3、物体表面、地面每日用含氯消毒剂清洁两次,并有记录。
3.保存诊室整齐,非诊疗用品不得存放入内。
3、保持诊疗床等物体表面清洁,诊疗床单使用一次性中单,如被污染应及时更换。
4、超声探头一人一用一清洁一消毒或灭菌;每班次检查结束后,对超声探头进行彻底清洁、消毒处理,干燥保存。
5、使用后的心电图电极头用75%酒精擦拭消毒;心电图机身及导联线保持清洁。
6、所有医疗废物(手套、帽子、口罩、使用后的卫生纸)均放入专用垃圾桶内,不得随意丢弃,并认真登记,双人签字
7、工作人员注意手卫生,配备洗手液及快速手消毒剂,接触病人皮肤、黏膜后要及时洗手。
8.将医院感染有关资料存放入专用文件夹内
第四篇:b超室的医院感染管理办法b超室医院感染防控办法
为保护医务人员的职业安全,有效预防医源性感染,根据《医院感染管理办法》、《消毒隔离规范》和《上海市超声质控手册》内容,特制订b超室医院感染防控办法,望参照执行。
一、做好室内环境、空气消毒,每天用紫外线灯照射消毒一次,至少2小时;对床、座椅、门把手等每天要用84消毒剂(浓度500mg/l)擦拭两次。并做好记录。
二、地面等如被患者血迹污染,要用浓度为1000mg/l的84消毒剂拖地两遍。
三、给特殊感染病人做b超检查时应带手套,一般情况下b超室的医生护士全戴卫生手套接诊没必要。但应该提醒和督促b超室的医生护士在检查完每一个病人后都应执行手卫生,即保护自己也保护病人的安全。一般接触皮肤的探头必要时可用一次性手套或专用探头套、阴超使用前加套可靠的消毒隔离套,发生破裂应用75%酒精擦拭2遍,肥皂水轻擦3分钟及流动水冲洗2分钟再吸干后用。除了
如果只戴着一副手套,从一个病人检查到另一个病人,而不更换的,是不对的。如果不更换手套其目的只为保护自己,但也没有真正保护自己,手套的透气性很差,试想套在手套里的手会是怎样的感觉,手套内的温度、湿度更是细菌繁殖的温床。
如果想保护自己同时保护病人,要么每病人更换手套(成本太高哦),要么速干手消毒液擦手。
新出的隔离规范对手套的使用有明确的规定。
在接触患者血液、体液、分泌物、排泄物、呕吐物及污染物品时,戴清洁手套;进行无菌操作时,接触破损皮肤粘膜时,戴无菌手套。b超室的医生护士不应该戴手套接诊或做b超检查。注意手卫生,注意探头的消毒,医疗废物的处理。常用福尔马林熏蒸消毒或用无菌乳胶包绕。具有防水性能的探头,可采用消毒液中浸泡的方法消毒。可以用75%乙醇擦拭消毒,其效果不亚于异丙醇。一般病人,检查后用草纸擦拭耦合剂,1
阴超用塑料薄膜套,一人一换。普通b超(接触完好皮肤的),检查后用草纸擦拭耦合剂,再用75%乙醇擦拭消毒即可.
阴超之类可用2%的戊二醛消毒处理10分钟,然后用灭菌蒸馏水冲洗干净即可。
注。一切探头均禁用碘酒、有机汞、有机溶剂、过氧乙酸、酸性液、碱性液等清洗。所以不知2%的戊二醛是否损害探头。
b超下进行穿刺的,探头清洗消毒后再套上灭菌保鲜袋
接触皮肤的医疗用具都应达到消毒水平,所以是要消毒的,而且应该是一用一消毒才符合感染控制的要求,但是目前存在很多的问题,比如病人太多,根本没有时间消毒,一般用卫生纸擦掉耦合剂后就直接用到下个病人上了;因为b超探头是有机材料,75%酒精及含氯消毒剂都会对其造成较大的影响(腐蚀,变形),一般大厂家的b超都会在说明书里说明不允许使用75%酒精及含氯消毒剂;具体使用哪一类的消毒剂您可以根据设备厂家说明书的推荐来使用;
若是b超探头是直接使用在手术野上,就更麻烦了,必须要灭菌,10h的戊二醛浸泡会不会对探头造成腐蚀。;消毒剂可能会对探头的灵敏度造成影响,我们医院采用类似保鲜袋的一次性探头套,效果不错,可以试试。
耦合剂达到无菌是否要求太高,普通b超(非手术野使用)接触皮肤达到消毒的水平应该就可以了,但是听厂家推荐过耦合剂里含消毒剂的,但是没有具体看到说明书和卫生部的批件;
曾经和传染病院的老师具体探讨过这个问题,目前b超主要的问题主要在2方面:
1,医生的习惯,普通b超每个病人都去消毒太浪费时间,b超探头不是压舌板可以使用一次性的;另外可能是厂家说耦合剂里含消毒剂,就凑合用了;我认为如果每用一个病人做一些必要的清洁就可以了,每日做一次消毒(中高水平),目前已经有关于b超探头污染严重的文献;
2,目前没有好的消毒剂能够安全(不腐蚀探头)快速(不耽误正常工作)的去用于b超探头
通常采用清水或酒精擦拭,要求对检查部位有明显血液等污染的,先用碘
伏进行检查部位皮肤的消毒,然后再检查。
第五篇:医院b超室工作制度目录
差错事故登记报告处理制度························································································2超声检查工作制度········································································································3超声检查须知················································································································4超声设备操作规程········································································································5
超声心电图室负责人职责····························································································6超声心电图室医师(士)职责························································································7超声心电图室主治医师职责························································································8计算机管理制度············································································································9检查室查对制度··········································································································10请示报告制度··············································································································10心电图设备操作规程··································································································11心电图检查工作制度··································································································12超声科就诊流程图······································································································14
差错事故登记报告处理制度
1、科室应建立医疗差错、事故登记、讨论、报告制度,由科主任指派专人登记发生差错、事故的原因、经过、结果,务必做到及时、准确并及时组织讨论总结。
2、凡发生医疗差错、事故或可能发生医疗差错、事故的事件,当事人应立即向本科室负责人报告,力求妥善处理,并登记入册。科室负责人及时向医务科报告。对重大事故,应做好善后工作。如不及时(立即)汇报或有意隐瞒,将视情节轻重予以严肃处理。
3、差错事故发生后,医务科或其他有关部门,要认真调查事发的详细经过,必须当班或当时完成调查(含讨论),尽快做出准确科学的结论。由医院依照有关规定进行处理,必要时上报上级卫生行政部门。
4、医务科在组织调查处理差错、事故过程中,应有专人保管有关病案和资料,任何人不得涂改、伪造、隐藏、销毁、丢失,违者按情节轻重予以严肃处理。
5、查明差错、事故原因,必要时由院、科向患者及家属作详细说明。其他任何人不得随意向患者及家属解释。必须严格遵守保护性医疗措施。
6、查明差错、事故原因,科主任应视不同情况对有关人员进行批评教育或行政处分,情节严重的严肃处理。
7、科主任及专业组长加强对差错事故的防范管理及对检查人员的安全医疗教育,经常检查、分析,发现隐患并及时解决。
2
超声检查工作制度
*超声检查包括b超、彩超检查。
*检查前做好一切准备工作,工作人员穿工作衣,医行端庄,整洁室内环境、工作台面及检查用床,备齐检查所需用品。一切物品放置正规有序。
*凡需做超声检查诊断的病员,由医师填写申请单,到超声科办理预约手续,工作人员应向病人或陪同人员详细交待检诊注意事项。*检查前应详细阅读申请内容。危重病员检查时应有医护人员护送或到床边检查,出现阳性结果应当反复核查,病变图象应拍照记录,疑难病例应会同有关医师检诊。
*超声检查完毕后,应尽快发出报告,报告单书写做到格式正确、项目填写齐全、字迹清楚、内容描述精确、签全名,进修实习生不能单独发报告,必须经带教医师复查后才能发报告。遇疑难问题应与临床医师联系,共同研究解决。按规定做资料登记,编号归档。
*下班前全面整理室内环境卫生,用物归位,保持室内整洁。爱护一切公物,不得损坏、浪费、私用,违者按章处理。
*经常深入各临床科室,了解检查结果的阳性率和诊断符合率,总结经验,不断提高诊断质量。住院病员超声检查出现阳性结果或可疑的阳性所见时,应与临床科取得联系,坚持追踪随访,对误诊,漏诊的病例应组织全科讨论,总结经验教训,提高诊断质量。
3*超声图像照片由超声诊室统一保管。临床科借用办理借用手续。各种检查提示应保管好,建立档案,经批准和登记手续后才能借出。
*指定专人保管仪器,严格遵守仪器操作规程,定期消毒仪器和用具,定期保养维修,并做好使用、维修记录,注意用电安全,严防差错事故发生。保持诊室清洁,对传染病患者用过的器物,做好消毒隔离工作,防止交叉感染。冬季应注意保暖,室内禁止吸烟。
*诊断穿刺时,必备抢救器械,穿刺诊疗必须由超声主治医师以上职称人员担任,严格遵守操作规程,保证质量安全。
*严禁利用超声技术进行非医学需要的胎儿性别鉴定和选择性人工终止妊娠,违者将重处。
超声检查须知
一、请您挂号后首先在医生处开具“检查申请单”,并在收费室缴纳检查费用(住院患者直接到住院收费处盖章),然后到检查室预约、排队,了解具体准备事宜。
二、为了尽量减小对检查者及被检查者的影响,给病人提供一个良好的就诊环境,检查时请其他无关人员不要进入检查室。
三、胎儿彩超检查宜怀孕6~7月进行。
四、各种检查准备:
4
1、消化系检查(肝胆胰脾等):
需禁食、禁水8~12小时,宜上午空腹进行。
此处内容需要权限查看
会员免费查看超声医生按标准模板文本撰写检查报告
打印报告
发出报告